Temptronic's ThermoStreams are portable systems that deliver clean dry air for precision temperature testing or conditioning of electronics (ICs, MEMS, transceivers, or circuits) and materials. No other systems can bring your test subjects to temperature faster with precise control.

With rapid thermal cycling or long saturation at a precise temperature, these systems optimize throughput for characterization, verification, thermal shock or failure analysis applications – at the test bench or on the production floor.

Features

  • No LN2 or LCO2 required
  • -100 to +300°C
  • Programmable transitions, up to 15°C/sec
  • 1.0°C accuracy
  • Extended reach for easy DUT access
  • Integrated purging system prevents moisture buildup on the DUT

500 & 600 Series Mobile Temperature Environments

1  2 3 4
Model ATS-505,605 ATS-515,615 ATS-525,625 ATS-535,635 ATS-545,645
LN2 or LCO2 not required
Temperature Range (at thermal head) -20 to +225°C -45 to +225°C -60 to +225°C -80 to +225°C
System Airflow Output 4 to 10 scfm (1.9 to 4.7 l/s) 4 to 10 scfm (1.9 to 4.7 l/s) 5 scfm (2.4 l/s) Fixed Flow 5 scfm (2.4 l/s) Fixed Flow 4 to 18 scfm (1.8 to 8.5 l/s) Continuous
Transition Rates 0 to +125°C, < 3 min +125 to 0°C, < 4 min -40 to +125°C, < 12 sec +125 to -40°C, < 40 sec -40 to +125°C, < 12 sec +125 to -40°C, < 40 sec -40 to +125°C, < 12 sec +125 to -40°C, < 40 sec -55 to +125°C, < 10 sec +125 to -55°C, < 10 sec
Temperature Display & Resolution ±1°C ±1°C ±1°C ±1°C ±1°C
Temperature Accuracy ±1°C ±1°C ±1°C ±1°C ±1°C
Directly Control Device Under Test (DUT)
DUT Control Sensors Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples
Remote interface IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232
Thermal Cap with protection from condensation at DUT site
Compact, portable system Fits bench top Easily integrates to bench top Easily integrates to bench top LabView™ drivers LabView™ drivers
CE Compliant and CFC-free
Facility requirements CDA at 90 psi minimum; Various power requirements available 130-240 VAC, 50/60Hz Built-in compressor; No facility air needed Same as ATS-505 to 625

700 & 800 Series Mobile Temperature Environments

8 7 6 5
Model ATS-710, 810 ATS-730,830 ATS-750,850 ATS-770,870
LN2 or LCO2 not required
Temperature Range (at thermal head) -80 to +225°C -90 to +225°C -90 to +300°C -100 to +225°C
System Airflow Output 4 to 18 scfm (1.8 to 8.5 l/s) Continuous 4 to 18 scfm (1.8 to 8.5 l/s) Continuous 4 to 18 scfm (1.8 to 8.5 l/s) Continuous 4 to 12 scfm (1.8 to 5.6 l/s) Continuous
Transition Rates -55 to +125°C, < 10 sec +125 to -55°C, < 10 sec -55 to +125°C, < 10 sec +125 to -55°C, < 10 sec -40 to +125°C, < 12 sec +125 to -40°C, < 40 sec -55 to +125°C, <10 sec +125 to -55°C, <10 sec
Temperature Display & Resolution ±1°C ±1°C ±1°C ±1°C
Temperature Accuracy ±1°C ±1°C ±1°C ±1°C
Directly Control Device Under Test (DUT)
DUT Control Sensors Type T or K Thermocouples, RTD (100 Ohm) Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples, RTD (100 Ohm)
Remote interface IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232
Thermal Cap with protection from condensation at DUT site
LabView™ drivers
CE Compliant and CFC-free
Heated Defrost -
Reduced Power Mode - heat only when using cold temperatures -
Automatic Power Reduction - reduce power usage during idle time -
Mechanical Arm or Turret Configuration
Optional Extended Height & Reach configuration for Mechanical Arm
Thermal Cap size options & Flexhose to connect external thermal chamber or test enclosure
Facility requirements CDA at 90 psi minimum; Various power requirements available 130-240 VAC, 50/60Hz