FluidChill™ process chillers are a family of high-reliability, portable temperature control systems for low and ultra-low process cooling. FluidChill systems provide high capacity cooling for demanding applications in industries such as automotive, energy, chemical processing, industrial, and semiconductor.

In-house design capabilities including thermodynamic, mechanical, electrical, and software, and on-site manufacturing ensure that your total chiller package will perform to specifications.

Chillers provide a touch screen controller, remote communications, real-time graphing, system diagnostics, and a variety of heat transfer fluids.

Available in both Water-cooled and Air-cooled configurations..

Water Cooled Chillers

Model Temperature Range (°C) Stability (°C) Cooling Capacity (kW @ 20°C Water Supply) Pump Capacity (GPM/LPM)
25 0 -20 -40 -45 -60 -70 -80
W-40-1100 -40 to +50 ±0.5 8.0 8.0 4.6 1.1 0.6 4 (15)
W-40-2000 -40 to +50 ±0.5 10.0 10.0 6.0 2.0 1.0 6 (23)
W-40-3100 -40 to +50 ±0.5 15.5 15.5 10.0 3.1 1.4 10 (38)
W-60-2800 -60 to +50 ±0.5 4.0 4.0 3.7 3.2 3.1 2.8 2.8 (11)
W-60-3100 -60 to +50 ±0.5 4.7 4.7 4.3 3.7 3.6 3.1 1.1 6 (23)
W-60-4700 -60 to +50 ±0.5 6.8 6.8 6.2 5.4 5.2 4.7 4.0 8 (30)
W-80-600 -80 to +50 ±0.5 2.5 2.5 2.3 2.1 2.0 1.8 1.6 0.6 2.8 (11)
W- 80-1800 -80 to +50 ±0.5 3.5 3.5 3.2 2.9 2.8 2.4 2.2 1.8 6 (23)
W-80-2500 -80 to +50 ±0.5 5.1 5.1 4.5 4.0 3.9 3.4 3.2 2.5 8 (30)


Air Cooled Chillers

Model Temperature Range (°C) Stability (°C) Cooling Capacity (kW @ 20°C Water Supply) Pump Capacity (GPM/LPM)
25 0 -20 -40 -45 -60 -70 -80
W-40-1100 -40 to +50 ±0.5 8.0 8.0 4.6 1.1 0.6 4 (15)
W-40-2000 -40 to +50 ±0.5 10.0 10.0 6.0 2.0 1.0 6 (23)
W-40-3100 -40 to +50 ±0.5 15.5 15.5 10.0 3.1 1.4 10 (38)
W-60-2800 -60 to +50 ±0.5 4.0 4.0 3.7 3.2 3.1 2.8 2.8 (11)
W-60-3100 -60 to +50 ±0.5 4.7 4.7 4.3 3.7 3.6 3.1 1.1 6 (23)
W-60-4700 -60 to +50 ±0.5 6.8 6.8 6.2 5.4 5.2 4.7 4 8 (30)
W-80-600 -80 to +50 ±0.5 2.5 2.5 2.3 2.1 2.0 1.8 1.6 0.6 2.8 (11)
W- 80-1800 -80 to +50 ±0.5 3.5 3.5 3.2 2.9 2.8 2.4 2.2 1.8 6 (23)
W-80-2500 -80 to +50 ±0.5 5.1 5.1 4.5 4.0 3.9 3.4 3.2 2.5 8 (30)


Process Chiller Controller:

  • Displays critical parameters such as supply and return temperature and pressure
  • Alarms for out-of-temperature range, low process flow, low reservoir level, and more
  • Logs diagnostics such as component run time, valve cycle count, ambient and enclosure temperatures
  • Displays temperature graphing
  • Communicates via Ethernet, RS-232, USB
  • Logs data, accessible via remote communications
  • CE and RoHS compliant

Notes

  1. Fluid pressure for all water-cooled and air-cooled models is 50 PSIG or less.
  2. -40 and -60°C performance achieved with Syltherm XLT fluid. -80°C performance achieved with HFE-7100 fluid.
  3. Consult factory for applications using other heat transfer fluids and flow rates.
Enquiry